Description
UTE load cells are designed to meet the most stringent accuracy requirements.
UDS? load cells are available in the capacities 20 t? to 30 t.
They are designed for weigh bridges, Vehicle scale, rail scaleThey offer total alloy
steel construction ,making them suitable for use in the toughest industrial environments.
Important Features:
1.? Capacities:20t,25t,30t
2. ?High accuracy
?????? ?3. ?Integral overload protection up to nominal load of 2000Kg
4.? Total alloy steel construction
5.? Factory mutual approved
Application areas:
?????? 1.? Vehicle scales
2.? Rail scales
UDS Specifications
|
Maximum Capacity
|
t |
20/25/30 |
Material
|
? |
Alloy steel
|
Recommended Excitation
|
V |
10
|
Maximum Excitation
|
V |
15
|
Rated Output(=RO)
|
mV/V |
2 ± 0.004 |
Zero Balance
|
%RO |
± 1
|
Creep Error (20minutes)
|
%RO |
± 0.03
|
Repeatability
|
%RO |
± 0.02
|
Input Resistance
|
Ω |
700 ± 7
|
Output Resistance
|
Ω |
700 ± 7
|
Compensated Temperature Range
|
|
-10 ~ 40
|
Operating Temperature Range
|
|
-20 ~ 60
|
Temperature Effect On Output
|
%Load/10 |
0.02 |
Temperature Effect On Zero
|
%RO/10 |
0.02
|
Safe Load limit
|
%of rat.cap. |
120
|
Ultimate load
|
%of rat.cap. |
150
|
Sealing
|
? |
Complete hermetic sealing;cable entry sealed by metal header |
Protection class
|
? |
IP 66 |
|