Description
TE load cells are designed to meet the most stringent accuracy requirements.
UKS? load cells are available in the capacities 20 Kg to 100 Kg.
They offer total alloy steel construction and complete hermetic sealing,making them
suitable for use in the toughest industrial environments.
Important Features:
??1. High accuracy
2. Complete hermetic sealing
3. Easy cable replacement
4. Complete range of loading hardware available
5.?Factory mutual approved
Application areas:
? 1. Tensile testing
2. Belt scale
3. Industrial scales
UKS Specifications
|
Maximum Capacity
|
Kg |
UKS-E 20/50/100 |
UKA-E 1/2/5/10/20 |
Material
|
|
Alloy steel |
Alumininum |
Recommended Excitation
|
V |
10
|
Maximum Excitation
|
V |
15
|
Rated Output(=RO)
|
mV/V |
1± 01 |
Zero Balance
|
%RO |
± 0.04
|
Creep Error (20minutes)
|
%RO |
± 0.05
|
Repeatability
|
%RO |
± 0.02
|
Input Resistance
|
Ω |
390 ± 3 |
394 ± 3 |
Output Resistance
|
Ω |
350 ± 3
|
Compensated Temperature Range
|
|
-10 ~ 40
|
Operating Temperature Range
|
|
-10 ~ 50
|
Temperature Effect On Output
|
%Load/10 |
0.02 |
Temperature Effect On Zero
|
%RO/10 |
0.02
|
Safe Load limit
|
%of rat.cap. |
150
|
Ultimate load
|
%of rat.cap. |
200
|
Sealing
|
|
Silicone |
Protection class
|
|
IP 66 |
|