辰东,玄幻小说 http://cnjhjh.cn/en/ Sat, 15 Aug 2015 14:59:26 +0000 en-US hourly 1 https://wordpress.org/?v=6.1.1 Load Cell UKS-E,UKA-E http://cnjhjh.cn/en/shop/load-cell-uks-e-uka-e/ http://cnjhjh.cn/en/shop/load-cell-uks-e-uka-e/#respond Tue, 11 Aug 2015 07:37:14 +0000 http://ute.shejiku.net/?post_type=product&p=16469 1. High accuracy
2. Complete hermetic sealing
3. Easy cable replacement
4. Complete range of loading hardware available
5.?Factory mutual approved

[dt_button size="medium" style="default" animation="none" color_mode="default" icon="" icon_align="left" color="" link="http://ute.en.alibaba.com/product/266502591-209514673/Load_cell.html" target_blank="true"]BUY[/dt_button]

The post Load Cell UKS-E,UKA-E first appeared on .

]]>
TE load cells are designed to meet the most stringent accuracy requirements.
UKS? load cells are available in the capacities 20 Kg to 100 Kg.
They offer total alloy steel construction and complete hermetic sealing,making them
suitable for use in the toughest industrial environments.

Important Features:
??1. High accuracy
2. Complete hermetic sealing
3. Easy cable replacement
4. Complete range of loading hardware available
5.?Factory mutual approved

Application areas:
? 1. Tensile testing
2. Belt scale
3. Industrial scales

UKS Specifications

Maximum Capacity

Kg UKS-E 20/50/100 UKA-E 1/2/5/10/20
Material
Alloy steel Alumininum
Recommended Excitation
V

10

Maximum Excitation

V

15

Rated Output(=RO)

mV/V 1± 01

Zero Balance

%RO

± 0.04

Creep Error (20minutes)

%RO

± 0.05

Repeatability

%RO

± 0.02

Input Resistance

Ω 390 ± 3 394 ± 3

Output Resistance

Ω

350 ± 3

Compensated Temperature Range

-10 ~ 40

Operating Temperature Range

-10 ~ 50

Temperature Effect On Output
%Load/10 0.02
Temperature Effect On Zero
%RO/10

0.02

Safe Load limit

%of rat.cap.

150

Ultimate load

%of rat.cap.

200

Sealing
Silicone
Protection class
IP 66

The post Load Cell UKS-E,UKA-E first appeared on .

]]>
http://cnjhjh.cn/en/shop/load-cell-uks-e-uka-e/feed/ 0
Load Cell UAA http://cnjhjh.cn/en/shop/load-cell-uaa/ http://cnjhjh.cn/en/shop/load-cell-uaa/#respond Tue, 11 Aug 2015 07:34:21 +0000 http://ute.shejiku.net/?post_type=product&p=16467 UTE load cells are designed to meet the most stringent accuracy requirements.
UAA universal load cells areavailable in the capacities 100 Kg to 500Kg.
They offer total alloy aluminum construction and complete hermetic sealing,
making them suitable for use in the toughest industrial environments

[dt_button size="medium" style="default" animation="none" color_mode="default" icon="" icon_align="left" color="" link="http://ute.en.alibaba.com/product/515898810-209514673/low_cost_load_cell.html" target_blank="true"]BUY[/dt_button]

The post Load Cell UAA first appeared on .

]]>
UTE load cells are designed to meet the most stringent accuracy requirements.
UAA universal load cells areavailable in the capacities 100 Kg to 500Kg.
They offer total alloy aluminum construction and complete hermetic sealing,
making them suitable for use in the toughest industrial environments

Important Features:
?????????? 1.? capacities:100Kg,250Kg,500Kg
2.? High accuracy
3.? Total aluminum construction
4.? Complete hermetic sealing
5.??Easy cable replacement
6.? Complete range of loading hardware available

?????????? 7. ?Factory mutual approved

Application areas:
1.? Crane scale
2.? Belt scale
3.? Tensile testing
4.? Silo and tank weighing
5.? Industrial scales
6. ?Mechanical coversion kits

UAA Specifications

Maximum Capacity

Kg 100/250/500
Material
?

Aluminum

Recommended Excitation
V

10

Maximum Excitation

V

15

Rated Output(=RO)

mV/V 2 ± 0.05

Zero Balance

%RO

± 0.030

Creep Error (20minutes)

%RO

± 0.04

Repeatability

%RO

± 0.02

Input Resistance

Ω

390 ± 3

Output Resistance

Ω

350 ± 3

Compensated Temperature Range

?

-10 ~ 40

Operating Temperature Range

-20 ~ 60

Temperature Effect On Output
%Load/10 0.02
Temperature Effect On Zero
%RO/10

0.02

Safe Load limit

%of rat.cap.

150

Ultimate load

%of rat.cap.

200

Sealing
? Complete hermetic sealing;cable entry sealed by metal header
Protection class
? IP 66

The post Load Cell UAA first appeared on .

]]>
http://cnjhjh.cn/en/shop/load-cell-uaa/feed/ 0
Load cell UAS http://cnjhjh.cn/en/shop/load-cell-uas/ http://cnjhjh.cn/en/shop/load-cell-uas/#respond Tue, 11 Aug 2015 07:04:38 +0000 http://ute.shejiku.net/?post_type=product&p=16466 UTE load cells are designed to meet the most stringent accuracy requirements.
UAS universal load cells are available in the capacities 250 Kg to 750 Kg.
They offer total alloy steel construction and complete hermetic sealing,making
them suitable for use in the toughest industrial environments.

[dt_button size="medium" style="default" animation="none" color_mode="default" icon="" icon_align="left" color="" link="http://ute.en.alibaba.com/product/266500732-209514673/Load_cell.html" target_blank="true"]BUY[/dt_button]

The post Load cell UAS first appeared on .

]]>
UTE load cells are designed to meet the most stringent accuracy requirements.

UAS universal load cells are available in the capacities 250 Kg to 750 Kg.
They offer total alloy steel construction and complete hermetic sealing,making
them suitable for use in the toughest industrial environments.

Important Features:
1. Capacities:250Kg,500Kg,750Kg
2. High accuracy
3. Total alloy steel construction
4. Complete hermetic sealing
5. Easy cable replacement
6. Complete range of loading hardware available
7. Factory mutual approved

Application areas:
?? ? 1. Crane scale
2. Belt scale
3. Tensile testing
4. Silo and tank weighing
5. Industrial scales
6. Mechanical coversion kits

UAS Specifications

Maximum Capacity

Kg 250 500/700
Material
?

Alloy steel

Recommended Excitation
V

10

Maximum Excitation

V

15

Rated Output(=RO)

mV/V 2 ± 0.05

3 ± 0.0025

Zero Balance

%RO

± 0.030

Creep Error (20minutes)

%RO

± 0.04

Repeatability

%RO

± 0.02

Input Resistance

Ω

390 ± 3

Output Resistance

Ω

350 ± 3

Compensated Temperature Range

-10 ~ 40

Operating Temperature Range

-20 ~ 60

Temperature Effect On Output
%Load/10 0.02
Temperature Effect On Zero
%RO/10

0.02

Safe Load limit

%of rat.cap.

150

Ultimate load

%of rat.cap.

200

Sealing
? Complete hermetic sealing;cable entry sealed by metal header
Protection class
? IP 66
?

The post Load cell UAS first appeared on .

]]>
http://cnjhjh.cn/en/shop/load-cell-uas/feed/ 0
Load cell UDS http://cnjhjh.cn/en/shop/load-cell-uds/ http://cnjhjh.cn/en/shop/load-cell-uds/#respond Tue, 11 Aug 2015 06:53:34 +0000 http://ute.shejiku.net/?post_type=product&p=16465 1.? Capacities:20t,25t,30t
2. ?High accuracy
?????? ?3. ?Integral overload protection up to nominal load of 2000Kg
4.? Total alloy steel construction
5.? Factory mutual approved

[dt_button size="medium" style="default" animation="none" color_mode="default" icon="" icon_align="left" color="" link="http://ute.en.alibaba.com/product/266484386-209514673/Load_cell.html" target_blank="true"]BUY[/dt_button]

The post Load cell UDS first appeared on .

]]>
 

UTE load cells are designed to meet the most stringent accuracy requirements.
UDS? load cells are available in the capacities 20 t? to 30 t.
They are designed for weigh bridges, Vehicle scale, rail scaleThey offer total alloy
steel construction ,making them suitable for use in the toughest industrial environments.

Important Features:
1.? Capacities:20t,25t,30t
2. ?High accuracy
?????? ?3. ?Integral overload protection up to nominal load of 2000Kg
4.? Total alloy steel construction
5.? Factory mutual approved

Application areas:
?????? 1.? Vehicle scales
2.? Rail scales

UDS Specifications

Maximum Capacity

t 20/25/30
Material
?

Alloy steel

Recommended Excitation
V

10

Maximum Excitation

V

15

Rated Output(=RO)

mV/V 2 ± 0.004

Zero Balance

%RO

± 1

Creep Error (20minutes)

%RO

± 0.03

Repeatability

%RO

± 0.02

Input Resistance

Ω

700 ± 7

Output Resistance

Ω

700 ± 7

Compensated Temperature Range

-10 ~ 40

Operating Temperature Range

-20 ~ 60

Temperature Effect On Output
%Load/10 0.02
Temperature Effect On Zero
%RO/10

0.02

Safe Load limit

%of rat.cap.

120

Ultimate load

%of rat.cap.

150

Sealing
? Complete hermetic sealing;cable entry sealed by metal header
Protection class
? IP 66

The post Load cell UDS first appeared on .

]]>
http://cnjhjh.cn/en/shop/load-cell-uds/feed/ 0
Load Cell UEAF http://cnjhjh.cn/en/shop/load-cell-ueaf/ http://cnjhjh.cn/en/shop/load-cell-ueaf/#respond Tue, 11 Aug 2015 06:44:24 +0000 http://ute.shejiku.net/?post_type=product&p=16464 1.? Capacities:35Kg,60Kg,100Kg,200Kg,300Kg,500Kg
2.??High accuracy
3.? Total alloy aluminum construction
4.? Low profile
5.? Easy cable replacement

[dt_button size="medium" style="default" animation="none" color_mode="default" icon="" icon_align="left" color="" link="http://ute.en.alibaba.com/product/516261835-209514673/wireless_load_cell.html" target_blank="true"]BUY[/dt_button]

The post Load Cell UEAF first appeared on .

]]>
UTE load cells are designed to meet the most stringent accuracy requirements.
???UEA? load cells are available in the capacities 35 Kg to 500 Kg.
They offer total alloy aluminum construction and improved potting,making them suitable
for use in the toughest industrial environments.
It allows very low profile platform design and offers advantages in all? kind of? weighing
applications

Important Features:
1.? Capacities:35Kg,60Kg,100Kg,200Kg,300Kg,500Kg
2.??High accuracy
3.? Total alloy aluminum construction
4.? Low profile
5.? Easy cable replacement

????????6.? Complete range of loading hardware available
7.??Factory mutual approved

Application areas:
1. Bench scale
2.?Floor scale

UEA Specifications

Maximum Capacity

Kg UEA 35/60/100/200/300/500 UEAX 60/100/200/300/500
Material

Aluminum

Recommended Excitation
V

10

Maximum Excitation

V

15

Rated Output(=RO)

mV/V 2 ± 0.05

Zero Balance

%RO

± 0.030

Creep Error (20minutes)

%RO

± 0.025

Repeatability

%RO

± 0.02

Input Resistance

Ω

402 ± 3

Output Resistance

Ω

350 ± 3

Compensated Temperature Range

-10 ~ 40

Operating Temperature Range

-20 ~ 60

Temperature Effect On Output
%Load/10 0.02
Temperature Effect On Zero
%RO/10

0.02

Safe Load limit

%of rat.cap.

150

Ultimate load

%of rat.cap.

200

Sealing
Potted
Protection class
IP 66
Maximum Platform Size
mm 500 X 500

 

The post Load Cell UEAF first appeared on .

]]>
http://cnjhjh.cn/en/shop/load-cell-ueaf/feed/ 0
Load cell UES http://cnjhjh.cn/en/shop/load-cell-ues/ http://cnjhjh.cn/en/shop/load-cell-ues/#respond Tue, 11 Aug 2015 06:32:55 +0000 http://ute.shejiku.net/?post_type=product&p=16463 UTE load cells are designed to meet the most stringent accuracy requirements.
UES? load cells are available in the capacities 0.25 t? to 10 t.
They offer total alloy steel construction and improved potting,making them
suitable for use in the toughest industrial environments.

[dt_button size="medium" style="default" animation="none" color_mode="default" icon="" icon_align="left" color="" link="http://ute.en.alibaba.com/product/266476510-209514673/Load_cell.html" target_blank="true"]BUY[/dt_button]

The post Load cell UES first appeared on .

]]>

UTE load cells are designed to meet the most stringent accuracy requirements.
UES? load cells are available in the capacities 0.25 t? to 10 t.
They offer total alloy steel construction and improved potting,making them
suitable for use in the toughest industrial environments.
It allows very low profile platform design and offers advantages in all? kind
of? weighing? applications.


Important Features:

1. Capacities:0.25t,0.5t,1t,2t,2.5t,5t,10t
2. High accuracy
3. Total alloy steel construction
4. Low profile
5. Easy cable replacement
6. Complete range of loading hardware available
7. Factory mutual approved

Application areas:
??? 1. Plat form scale

?? ?2. Silo and tank weighing

UES Specifications

Maximum Capacity

t 0.25/0.5/1/2.5/5/10
Material
?

Alloy steel

Recommended Excitation
V

10

Maximum Excitation

V

15

Rated Output(=RO)

mV/V 3 ± 0.0025

Zero Balance

%RO

± 0.030

Creep Error (20minutes)

%RO

± 0.03

Repeatability

%RO

± 0.02

Input Resistance

Ω

390 ± 3

Output Resistance

Ω

350 ± 3

Compensated Temperature Range

-10 ~ 40

Operating Temperature Range

-20 ~ 60

Temperature Effect On Output
%Load/10 0.02
Temperature Effect On Zero
%RO/10

0.02

Safe Load limit

%of rat.cap.

150

Ultimate load

%of rat.cap.

200

Sealing
? Complete hermetic sealing;cable entry sealed by metal header
Protection class
? IP 66
?

The post Load cell UES first appeared on .

]]>
http://cnjhjh.cn/en/shop/load-cell-ues/feed/ 0
Load Cell UHA http://cnjhjh.cn/en/shop/load-cell-uha/ http://cnjhjh.cn/en/shop/load-cell-uha/#respond Mon, 10 Aug 2015 16:50:57 +0000 http://ute.shejiku.net/?post_type=product&p=16455 UTE load cells are designed to meet the most stringent accuracy requirements.

UHA? load cells are available in the capacities 0.3 Kg to 3 Kg.
They offer total alloy aluminum construction and improved potting,making them
suitable?? for use in the toughest industrial environments.
[dt_button size="medium" style="default" animation="none" color_mode="default" icon="" icon_align="left" color="" link="http://ute.en.alibaba.com/product/275032526-209514673/Load_cell.html" target_blank="true"]BUY[/dt_button]

The post Load Cell UHA first appeared on .

]]>

UTE load cells are designed to meet the most stringent accuracy requirements.

UHA? load cells are available in the capacities 0.3 Kg to 3 Kg.
They offer total alloy aluminum construction and improved potting,making them
suitable?? for use in the toughest industrial environments.
Important Features:
??? ? 1.? Capacities:0.3Kg,0.6Kg,1.2Kg,1.5Kg,3Kg
?? ?? 2.? High accuracy
?? ?? 3.? Total alloy aluminum construction
???? ?4.? Easy cable replacement
??? ? 5.? Complete range of loading hardware available
???? ?6.? Factory mutual approved
Application areas:
????? Precision balance
UBA Specifications
Maximum Capacity
Kg
0.3/0.6/1.2/1.5/3
Material
Aluminum
Recommended Excitation
V
10
Maximum Excitation
V
15
Rated Output(=RO)
mV/V
1± 0.10
Zero Balance
%RO
± 0.05
Creep Error (20minutes)
%RO
± 0.05
Repeatability
%RO
± 0.02
Input Resistance
Ω
394 ± 3
Output Resistance
Ω
350 ± 3
Compensated Temperature Range
-10 ~ 40
Operating Temperature Range
-20 ~ 60
Temperature Effect On Output
%Load/10
0.03
Temperature Effect On Zero
%RO/10
0.03
Safe Load limit
%of rat.cap.
150
Ultimate load
%of rat.cap.
200
Sealing
Potted
Protection class
IP 66
Maximum Platform Size
mm
200 X 20

The post Load Cell UHA first appeared on .

]]>
http://cnjhjh.cn/en/shop/load-cell-uha/feed/ 0
Load cell UGA http://cnjhjh.cn/en/shop/load-cell-uga/ http://cnjhjh.cn/en/shop/load-cell-uga/#respond Mon, 10 Aug 2015 16:49:11 +0000 http://ute.shejiku.net/?post_type=product&p=16454 UTE load cells are designed to meet the most stringent accuracy requirements.
???? ?UGA? load cells are available in the capacities 0.6 Kg to 3 Kg.
??????They offer total alloy aluminum construction and improved potting,making them
suitable? for use in the toughest industrial environments.
[dt_button size="medium" style="default" animation="none" color_mode="default" icon="" icon_align="left" color="" link="http://ute.en.alibaba.com/product/266499205-209514673/Load_cell.html" target_blank="true"]BUY[/dt_button]

The post Load cell UGA first appeared on .

]]>
?? UTE load cells are designed to meet the most stringent accuracy requirements.
???? ?UGA? load cells are available in the capacities 0.6 Kg to 3 Kg.
??????They offer total alloy aluminum construction and improved potting,making them
suitable? for use in the toughest industrial environments.
Important Features:
???? 1. Capacities:0.6Kg,1Kg,1.2Kg,1.5Kg,3Kg
???? 2.?High accuracy
???? 3. Total alloy aluminum construction
???? 4.?Easy cable replacement
??? ?5.?Complete range of loading hardware available
???? 6. Factory mutual approved
Application areas:
???? Precision balance
UBA Specifications
Maximum Capacity
Kg
0.6/1/1.2/1.5/3
Material
Aluminum
Recommended Excitation
V
10
Maximum Excitation
V
15
Rated Output(=RO)
mV/V
1± 0.10
Zero Balance
%RO
± 0.05
Creep Error (20minutes)
%RO
± 0.05
Repeatability
%RO
± 0.02
Input Resistance
Ω
394 ± 3
Output Resistance
Ω
350 ± 3
Compensated Temperature Range
-10 ~ 40
Operating Temperature Range
-20 ~ 60
Temperature Effect On Output
%Load/10
0.03
Temperature Effect On Zero
%RO/10
0.03
Safe Load limit
%of rat.cap.
150
Ultimate load
%of rat.cap.
200
Sealing
Potted
Protection class
IP 66

The post Load cell UGA first appeared on .

]]>
http://cnjhjh.cn/en/shop/load-cell-uga/feed/ 0
Load cell URA http://cnjhjh.cn/en/shop/load-cell-ura/ http://cnjhjh.cn/en/shop/load-cell-ura/#respond Mon, 10 Aug 2015 16:08:11 +0000 http://ute.shejiku.net/?post_type=product&p=16452 UTE load cells are designed to meet the most stringent accuracy requirements.
?? ?URA? load cell are available in the capacities 100 Kg to 750 Kg.
It allows very low profile platform design and offers advantages in all? kind of? weighing
applications.

[dt_button size="medium" style="default" animation="none" color_mode="default" icon="" icon_align="left" color="" link="http://ute.en.alibaba.com/product/266488481-209514673/Load_cell_URA.html" target_blank="true"]BUY[/dt_button]

The post Load cell URA first appeared on .

]]>
 

??? UTE load cells are designed to meet the most stringent accuracy requirements.
?? ?URA? load cell are available in the capacities 100 Kg to 750 Kg.
It allows very low profile platform design and offers advantages in all? kind of? weighing
applications.

Important Features:
1. Capacities:100Kg,150Kg,200Kg,300Kg,500Kg,750Kg
2. High accuracy
3. Total alloy aluminum construction
4. Low profile
5. Easy cable replacement
6. Complete range of loading hardware available
7. Factory mutual approved

Application areas:
1. Bench scale
2. Plat form scale
URA Specifications

Maximum Capacity

Kg 100/150/200/300/500/750
Material

Aluminum

Recommended Excitation
V

10

Maximum Excitation

V

15

Rated Output(=RO)

mV/V 2 ± 0.05

Zero Balance

%RO

± 0.030

Creep Error (20minutes)

%RO

± 0.025

Repeatability

%RO

± 0.02

Input Resistance

Ω

414 ± 3

Output Resistance

Ω

350 ± 3

Compensated Temperature Range

-10 ~ 40

Operating Temperature Range

-20 ~ 60

Temperature Effect On Output
%Load/10 0.02
Temperature Effect On Zero
%RO/10

0.02

Safe Load limit

%of rat.cap.

150

Ultimate load

%of rat.cap.

200

Sealing
Potted
Protection class
IP 66
Maximum Platform Size
mm 600 X 600

The post Load cell URA first appeared on .

]]>
http://cnjhjh.cn/en/shop/load-cell-ura/feed/ 0