遮天 辰东 小说,辰东完美世界有声小说,小说阅读器 http://cnjhjh.cn/en/ Tue, 11 Aug 2015 07:37:14 +0000 en-US hourly 1 https://wordpress.org/?v=6.1.1 Load Cell UKS-E,UKA-E http://cnjhjh.cn/en/shop/load-cell-uks-e-uka-e/ http://cnjhjh.cn/en/shop/load-cell-uks-e-uka-e/#respond Tue, 11 Aug 2015 07:37:14 +0000 http://ute.shejiku.net/?post_type=product&p=16469 1. High accuracy
2. Complete hermetic sealing
3. Easy cable replacement
4. Complete range of loading hardware available
5.?Factory mutual approved

[dt_button size="medium" style="default" animation="none" color_mode="default" icon="" icon_align="left" color="" link="http://ute.en.alibaba.com/product/266502591-209514673/Load_cell.html" target_blank="true"]BUY[/dt_button]

The post Load Cell UKS-E,UKA-E first appeared on .

]]>
TE load cells are designed to meet the most stringent accuracy requirements.
UKS? load cells are available in the capacities 20 Kg to 100 Kg.
They offer total alloy steel construction and complete hermetic sealing,making them
suitable for use in the toughest industrial environments.

Important Features:
??1. High accuracy
2. Complete hermetic sealing
3. Easy cable replacement
4. Complete range of loading hardware available
5.?Factory mutual approved

Application areas:
? 1. Tensile testing
2. Belt scale
3. Industrial scales

UKS Specifications

Maximum Capacity

Kg UKS-E 20/50/100 UKA-E 1/2/5/10/20
Material
Alloy steel Alumininum
Recommended Excitation
V

10

Maximum Excitation

V

15

Rated Output(=RO)

mV/V 1± 01

Zero Balance

%RO

± 0.04

Creep Error (20minutes)

%RO

± 0.05

Repeatability

%RO

± 0.02

Input Resistance

Ω 390 ± 3 394 ± 3

Output Resistance

Ω

350 ± 3

Compensated Temperature Range

-10 ~ 40

Operating Temperature Range

-10 ~ 50

Temperature Effect On Output
%Load/10 0.02
Temperature Effect On Zero
%RO/10

0.02

Safe Load limit

%of rat.cap.

150

Ultimate load

%of rat.cap.

200

Sealing
Silicone
Protection class
IP 66

The post Load Cell UKS-E,UKA-E first appeared on .

]]>
http://cnjhjh.cn/en/shop/load-cell-uks-e-uka-e/feed/ 0
Load Cell UAA http://cnjhjh.cn/en/shop/load-cell-uaa/ http://cnjhjh.cn/en/shop/load-cell-uaa/#respond Tue, 11 Aug 2015 07:34:21 +0000 http://ute.shejiku.net/?post_type=product&p=16467 UTE load cells are designed to meet the most stringent accuracy requirements.
UAA universal load cells areavailable in the capacities 100 Kg to 500Kg.
They offer total alloy aluminum construction and complete hermetic sealing,
making them suitable for use in the toughest industrial environments

[dt_button size="medium" style="default" animation="none" color_mode="default" icon="" icon_align="left" color="" link="http://ute.en.alibaba.com/product/515898810-209514673/low_cost_load_cell.html" target_blank="true"]BUY[/dt_button]

The post Load Cell UAA first appeared on .

]]>
UTE load cells are designed to meet the most stringent accuracy requirements.
UAA universal load cells areavailable in the capacities 100 Kg to 500Kg.
They offer total alloy aluminum construction and complete hermetic sealing,
making them suitable for use in the toughest industrial environments

Important Features:
?????????? 1.? capacities:100Kg,250Kg,500Kg
2.? High accuracy
3.? Total aluminum construction
4.? Complete hermetic sealing
5.??Easy cable replacement
6.? Complete range of loading hardware available

?????????? 7. ?Factory mutual approved

Application areas:
1.? Crane scale
2.? Belt scale
3.? Tensile testing
4.? Silo and tank weighing
5.? Industrial scales
6. ?Mechanical coversion kits

UAA Specifications

Maximum Capacity

Kg 100/250/500
Material
?

Aluminum

Recommended Excitation
V

10

Maximum Excitation

V

15

Rated Output(=RO)

mV/V 2 ± 0.05

Zero Balance

%RO

± 0.030

Creep Error (20minutes)

%RO

± 0.04

Repeatability

%RO

± 0.02

Input Resistance

Ω

390 ± 3

Output Resistance

Ω

350 ± 3

Compensated Temperature Range

?

-10 ~ 40

Operating Temperature Range

-20 ~ 60

Temperature Effect On Output
%Load/10 0.02
Temperature Effect On Zero
%RO/10

0.02

Safe Load limit

%of rat.cap.

150

Ultimate load

%of rat.cap.

200

Sealing
? Complete hermetic sealing;cable entry sealed by metal header
Protection class
? IP 66

The post Load Cell UAA first appeared on .

]]>
http://cnjhjh.cn/en/shop/load-cell-uaa/feed/ 0
Load cell UAS http://cnjhjh.cn/en/shop/load-cell-uas/ http://cnjhjh.cn/en/shop/load-cell-uas/#respond Tue, 11 Aug 2015 07:04:38 +0000 http://ute.shejiku.net/?post_type=product&p=16466 UTE load cells are designed to meet the most stringent accuracy requirements.
UAS universal load cells are available in the capacities 250 Kg to 750 Kg.
They offer total alloy steel construction and complete hermetic sealing,making
them suitable for use in the toughest industrial environments.

[dt_button size="medium" style="default" animation="none" color_mode="default" icon="" icon_align="left" color="" link="http://ute.en.alibaba.com/product/266500732-209514673/Load_cell.html" target_blank="true"]BUY[/dt_button]

The post Load cell UAS first appeared on .

]]>
UTE load cells are designed to meet the most stringent accuracy requirements.

UAS universal load cells are available in the capacities 250 Kg to 750 Kg.
They offer total alloy steel construction and complete hermetic sealing,making
them suitable for use in the toughest industrial environments.

Important Features:
1. Capacities:250Kg,500Kg,750Kg
2. High accuracy
3. Total alloy steel construction
4. Complete hermetic sealing
5. Easy cable replacement
6. Complete range of loading hardware available
7. Factory mutual approved

Application areas:
?? ? 1. Crane scale
2. Belt scale
3. Tensile testing
4. Silo and tank weighing
5. Industrial scales
6. Mechanical coversion kits

UAS Specifications

Maximum Capacity

Kg 250 500/700
Material
?

Alloy steel

Recommended Excitation
V

10

Maximum Excitation

V

15

Rated Output(=RO)

mV/V 2 ± 0.05

3 ± 0.0025

Zero Balance

%RO

± 0.030

Creep Error (20minutes)

%RO

± 0.04

Repeatability

%RO

± 0.02

Input Resistance

Ω

390 ± 3

Output Resistance

Ω

350 ± 3

Compensated Temperature Range

-10 ~ 40

Operating Temperature Range

-20 ~ 60

Temperature Effect On Output
%Load/10 0.02
Temperature Effect On Zero
%RO/10

0.02

Safe Load limit

%of rat.cap.

150

Ultimate load

%of rat.cap.

200

Sealing
? Complete hermetic sealing;cable entry sealed by metal header
Protection class
? IP 66
?

The post Load cell UAS first appeared on .

]]>
http://cnjhjh.cn/en/shop/load-cell-uas/feed/ 0